loading
Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa..

    Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa..

    RM 1,055.00

    Please select option below

    X

    Quantity
    - +
    5 left
    Ships From Oversea
    Estimated Arrival : 7-10 working days.
    First unit : RM 7.60 
    Shipping Fee
    RM 7.6 by courier to Peninsular Malaysia
    RM 11.95 by courier to Sabah, Labuan
    RM 11.95 by courier to Sarawak
    Ship To : Within Malaysia
    Save More $ - Combine Shipping Buyer is responsible for import duty / extra charge for custom clearance
    ADD TO CART
    BUY NOW
    Add to wishlist
    Since 24 Oct 2018
    We accept
    and more
    Buyer Protection
    with NetPay
    Full Refund if you don't receive your order*
    N/A
    Popular Products
    Product ID : 215703858
    Brand : Generic
    Model / SKU : 1013032
    Conditions : New


    Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa..

    Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa..


    Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa..


    Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa..

    Description:
    Hantek DSO5102P USB Digital Storage Oscilloscope 2Channels 100MHz 1GSa/s
    Features:
    100MHz bandwidths
    1GSa/s Real Time sample rate
    Large (7.0-inch) color display,WVGA(800x480)
    R'ecord length up to 40'K
    Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
    USB host and device connectivity, standard
    Multiple automatic measurements
    Four math functions, including FFTs standard
    Provides software for PC real-time analysis
    Specification:
    Model DSO5202P DSO5102P DSO5072P
    Acquisition
    Sample Rate Real-Time Sample: 1GS/s
    Equivalent Sample: 25GS/s
    Acquisition Modes
    Normal Normal data only
    Pea'k Detect High-frequency and randon glith capture
    Average Wavefom Average, selectable 4,8,16,32,64,128
    Inputs
    Inputs Coupling AC, DC, GND
    Inpits Impendance 1MΩ±2% II20pF±3pF
    Probe Attenuation 1X, 10X
    Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
    Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;
    CAT III: 150VRMS (1×);
    Installation Category II: derate at 20dB/decade above 100kHz to 13V Pea'k AC at 3MHz* and above.
    For non-sinusoidal waveforms, Pea'k value must be less than 450V.
    Excursion above 300V should be of less than 100ms duration.
    RMS signal level including all DC components removed through AC coupling must be limited to 300V.
    If these values are exceeded, damage to the oscilloscope may occur.
    Horizontal
    Sample Rate Range 500MS/s--1GS/s
    Waveform Interpolation (sin x)/x
    R'ecord Length 40'K
    SEC/DIV Range 4ns/div to 40s/div 4ns/div to 40s/div
    Sample Rate and
    Delay Time Accuracy
    ±50ppm(at over any ≥1ms time interval)
    Position Range 2ns/div to 10ns/div;
    (-4div x s/div) to 20ms;
    20ns/div to 80us/div; (-8div x s/div) to 40ms;
    200us/div to 40s/div; (-8div x s/div) to 400s
    Delta Time Measurement Accuracy
    (Full Bandwidth)
    Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
    >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
    Sample interval = s/div ÷ 200
    Vertical
    Vertical Resolution 8-bit resolution, all channel sampled simultaneously
    Position Range 2mV/div to 200mV/div, ±2V
    200mV/div to 5V/div, ±50V
    Bandwidth 100MHz 100MHz 70MHz
    Rise Time at BNC( typical) 3.5ns 3.5ns 5ns
    Analog Bandwidth in Normal and
    Average modes at BNC or with probe, DC Coupled
    2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V
    500mV/div to 2V/div, ±40V; 5V/div, ±50V
    Math +, -, *, /, FFT
    FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
    1024 sample point
    Bandwidth Limit 20MHz
    Low Frequency Response (-3db) ≤10Hz at BNC
    DC Gain Accuracy ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
    ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
    DC Measurement Accuracy,
    Average Acquisition Mode
    When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;
    When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div];
    Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
    Volts Measurement Repeatability,
    Average Acquisition Mode
    Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
    Trigger System
    Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
    Trigger Source CH1, CH2, EXT, EXT/5, AC Line
    Trigger Modes Auto, Normal, Single
    Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
    Trigger Sensitivity
    (Edge Trigger Type)
    DC(CH1,CH2):
    1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
    DC(EXT):
    200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
    DC(EXT/5):
    1V from DC to 100MHz;1.75V from 100MHz to 200MHz;
    AC: Attenuates signals below 10Hz;
    HF Reject: Attenuates signals above 80kHz;
    LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
    Trigger Level Range CH1/CH2: ±8 divisions from center of screen;
    EXT: ±1.2V;
    EXT/5:±6V
    Trigger Level Accuracy( typical)Accuracy
    is for signals having rise and fall times ≥20ns
    CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
    EXT: ± (6% of setting + 40mV);
    EXT/5: ± (6% of setting + 200mV);
    Set Level to 50%(typical) Operates with input signals ≥50Hz
    Video Trigger
    Video Trigger Type CH1, CH2: Pea'k-to-Pea'k amplitude of 2 divisions;
    EXT: 400mV;
    EXT/5: 2V
    Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
    Holdoff Range 100ns ~ 10s
    Pulse Width Trigger
    Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
    Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
    Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge.
    Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
    Less than: The trigger point is the trailing edge.
    Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
    Pulse Width Range 20ns ~ 10s
    Slope Trigger
    Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
    Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
    Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
    Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
    Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
    Time Range 20ns ~ 10s
    Overtime Trigger
    Over Time Mode Rising edge or Falling edge
    Time Range 20ns ~ 10s
    Alternative Trigger
    Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
    Trigger Frequency Counter
    Readout Resolution 6 digits
    Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
    Frequency Range AC coupled, from 4Hz Min to rated bandwidth
    Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
    The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses
    due to changes in the run status, or acquisition of a single shot event has completed.
    Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events,
    such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
    Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
    Video Trigger mode: The Frequency Counter does not work.
    Measure
    Cursor Measurement Voltage difference between cursors: ΔV
    Time difference between cursors: ΔT
    Reciprocal of ΔT in Hertz (1/ΔT)
    Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Min, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
    Display
    Display Type 7 inch 64K color TFT (diagonal liquid crystal)
    Display Resolution 800 horizontal by 480 vertical pixels
    Display Contrast Adjustable (16 gears) with the progress bar
    Probe Compensator Output
    Output Voltage( typical) About 5Vpp into ≥1MΩ load
    Frequency(typical) 1kHz
    Power Supply
    Supply Voltage 100-120VACRMS(±10%), 45Hz to 440Hz, CATII
    120-240VACRMS(±10%), 45Hz to 66Hz, CATII
    Power Consumption <30W
    Fuse 2A, T rating, 250V
    Environmental
    Temperature Operating: 32F to 122F (0C to 50C);
    Nonoperating: -40F to 159.8F (-40C to +71C)
    Cooling Method Convection
    Humidity +104F or below (+40C or below): ≤90% relative humidity;
    106F to 122F (+41C to 50C): ≤60% relative humidity
    Altitude Operating: Below 3,000m (10,000 feet);
    Nonoperaring: Below 15,000m(50,000 feet)
    Mechanical
    Size Length 385mm, Width 200mm, Height 245mm
    Weight 3.5KG(with Packing); 2.08KG(without Packing)

    Package includes:
    1 x Digital Storage Oscilloscope
    2 x Probes (PP150)
    1 x Oscilloscope Power line
    1 x Hantek data CD
    1 x USB line
    1 x Manufacturer Certificate
    Details pictures:



    ,,,,




    Buy with confidence
    We have 5 Good Ratings from buyers View More Rating >
    Buyer
    Item ID
    Date
    Ratings
    si****
    212244342
    4/25/2019 3:51:00 AM
    -
    ms****
    203029141
    3/21/2019 9:43:00 PM
    -
    kh****
    210553976
    2/25/2019 8:05:00 PM
    -
    s8****
    210393009
    1/30/2019 5:26:00 PM
    good seller
    yu****
    208970090
    1/16/2019 9:32:00 PM
    Fasting delivery. Nice stuff.
    ri****
    209948633
    12/19/2018 3:16:00 PM
    -

    After payment has been made, please send an email to marinagetrie@yahoo.com or sales@quantum-approach.com with following information:-
     
    Recipient Name:
    Shipping Address:
    Contact No:
    Total Price (Including Shipping Charge):
    Payment Date and Time:
     
    Alternatively, you can send a payment proof to +6016-8522194/+6019-2510449

    1. COURIER : POSLAJU OR GDEX

    2. DELIVERY PERIOD: ONE(1) to THREE(3) days after payment made.

    1. PRICE: We reserve the right to change the price mentioned without prior notice.
     
    2. PRODUCTS AVAILABILITY: The products availaibility are subject to change prior to sales. Should the products are out of stock, we will inform you with the option to change product or cancel your order and get a refund.
     
    3. SPECIFICATION: We warrant that the products sold conform to the specifications described. However, kindly allow tolerance for packaging and product color as it might varies.
     
    4. CANCELLATION: No order cancellation and refund allowed once payment has already been made.
     
    5. GUARANTEE: Every effort has been made to ensure your utmost satisfaction. Kindly contact us if there is any issue with the product or service delivered and we will do our best to solve the issue.
    1. WARRANTY: We offer ONE(1) year limited warranty for equipments and tools. However, if the equipments and tools are found to be faulty due to misusage, the warranty is VOID. For electronic components and consumable items, we offer ONE(1) month warranty only. Kindly contact us if you would like to ensure on the warranty period.
     
    2. RETURN POLICY: We do not accept any return items which are ordered wrongly by your side. Request for exchange of items can be considered.
    Average Product Rating

    0.0 stars out of 5
    5 star
    0
    4 star
    0
    3 star
    0
    2 star
    0
    1 star
    0
    Share your thoughts with others
    Write a review
    Only buyers who purchased the product may leave a review

    Frequently Bought Together

    Customers Who Bought This Item Also Bought

    Related Products

    QASBeStore Highlights

    Recently Viewed Items

    QASBeStore' Best Seller

    Promotion Items

    QASBeStore' Recently Sold

    QASBeStore' Items



    You may also be interested in Tag:



    Seller & Buyer Communication
    We provide a transparency communication between buyer & seller in a secure platform.
    Save Money & Time
    We give an access to everything buyer need at competitive prices.
    Secured & Protected
    All the information & transaction are secure with our Netpay system.
    MOBILE APPS
    app store
    google play
    RECEIVE NEWS & SPECIAL OFFERS TODAY
    Subscribe
    WE ACCEPT THE FOLLOWING PAYMENT METHODS
    netpay maybank publicbank cimb hongleong
    STAY CONNECTED
    Copyright © 2019 Interbase Resources Sdn. Bhd. (465435-U).
    All product names are trademarks of their respective companies.
    Lelong.my is not affiliated with or endorsed by any company listed on this site.