loading


PRECISION BALANCE, SARTORIUS, 8200G,0.1G

Our Price
RM 2,905.99
Price includes GST (6%)
Normal Price
RM 3,710.00    You save RM 804.01 (22%)
Shipping
*Incl GST (6%)
RM 12.72 by courier to Peninsular Malaysia
Every subsequent item add RM 0.00 
From Klang / Selangor , Estimated Arrival 1-3 working days.  
Please select option below

X

Quantity
- +
7 left
ItemID
187514529
Ship To
Within Malaysia ,Ship By: Courier Services,Self Collect,Normal Post
Views
47
Available Quantity
7
Seller Information
mylaboratories
Store since 27 Sep 2013
GST ID: 000334209024

Feedback Score
: 46+
Positive Feedback
: 100.00%
Total Product
: 741
NetPay
Buyer Protection Program
Payments are covered by BPP (Learn More)
Item Specification
  • Report
  • Model / SKU : SAR8201-1S
    Conditions : New

    Product Description


    PRECISION BALANCE, SARTORIUS, 8200G,0.1G

    Sartorius ENTRIS balances Specs:

    Model ENTRIS
    64-1S
    ENTRIS
    124-1S
    ENTRIS
    224-1S
    ENTRIS
    153-1S
    ENTRIS
    323-1S
    ENTRIS
    423-1S
    ENTRIS
    623-1S
    ENTRIS
    822-1S
    ENTRIS
    2202-1S
    ENTRIS
    3202-1S
    ENTRIS
    4202-1S
    ENTRIS
    6202-1S
    ENTRIS
    2201-1S
    ENTRIS
    5201-1S
    ENTRIS
    8201-1S
                                   
    Capacity x Readability 60 x 0.0001 g 120 x 0.0001 g 220 x 0.0001 g 150 x 0.001 g 320 x 0.001 g 420 x 0.001 g 620 x 0.001 g 820 x 0.01 g 2200 x 0.01 g 3200 x 0.01 g 4200 x 0.01 g 6200 x 0.01 g 2200 x 0.1 g 5200 x 0.1 g 8200 x 0.1 g
    Repeatability (standard deviation) 0.1 mg 0.1 mg 0.1 mg 1 mg 1 mg 1 mg 1 mg 10 mg 10 mg 10 mg 10 mg 10 mg 100 mg 100 mg 100 mg
    Linearity deviation 0.2 mg 0.2 mg 0.2 mg 2 mg 2 mg 2 mg 2 mg 30 mg 30 mg 30 mg 30 mg 30 mg 300 mg 300 mg 300 mg
    Sensitivity drift between +10 °C and +30 °C 3 ± ppm/K 3 ± ppm/K 3 ± ppm/K 3 ± ppm/K 3 ± ppm/K 3 ± ppm/K 3 ± ppm/K 4 ± ppm/K 4 ± ppm/K 4 ± ppm/K 4 ± ppm/K 4 ± ppm/K 8 ± ppm/K 8 ± ppm/K 8 ± ppm/K
    Typical stabilization time 2.5 s 2.5 s 2.5 s 1.3 s 1.1 s 1.0 s 1.0 s 1.5 s 1.5 s 1.5 s 1.5 s 1.5 s 1.5 s 1.5 s 1.5 s
    Weighing pan size 90 mm dia 115 mm dia 150 mm dia 180 x 180 mm 180 x 180 mm
    Weighing chamber height 173 + 176 + 240 mm -
    Net weight, approx. 4.4 kg 2.6 kg 3.2 kg 2.0 kg 3.1 kg 2.7 kg
    Calibration External
    Dimensions, D x W x H 230 x 303 x 330 mm 230 x 303 x 136 mm 230 x 303 x 87 mm 230 x 303 x 91 mm 230 x 303 x 91 mm
    9.1 x 11.9 x 13 Inch 9.1 x 11.9 x 5.4 Inch 9.1 x 11.9 x 3.4 Inch 9.1 x 11.9 x 3.6 Inch 9.1 x 11.9 x 3.6 Inch
    Levelling Glass level indicator with air bubble for centering
    Selectable weight units Grams, Kilograms, Carats, Pounds, Ounces, Troy ounces, Hong Kong taels, Singapore taels, Taiwan taels, Grains, Pennyweights, Milligrams, Parts per pound, China taels, Mommes, Austrian carats, Tola, Baht, Mesghal, Tons, Pounds: ounces, Newton
    Interface RS232C 25-pin
    Display White backlit, high-contrast display with 15 mm digits
    Standard built-in applications Weighing, Density, Percentage, Counting, Animal Weighing, Conversion
    Languages English, French, German, Italian, Polish, Russian, Spanish
    Anti-theft lock Lockdown capability for cable or chain
    Underfloor weighing Integrated
    Sartorius AC adaptor module 6971790 with interchangeable country-specific plug-in AC adaptors
    Primary pover 100 – 240 V~, –10% | +10%, 50 – 60 Hz, 0.2 A
    Secondary pover 15 V DC, ± 5%, 530 mA (max.) | 8 Watt (max.): 0 to +40 °C and
    15 V DC, ± 5%, 330 mA (max.) | 5 Watt (max.): 0 to +50 °C
    Other pover data protection class II, in accordance with EN | IEC 60950-1 up to 3000 m above sea level; IP40 as per EN | IEC 60529
    Power supply only via Sartorius AC adaptor module 6971790
    Input voltage 12.0 ... 18.0 V DC
    Power consumption 2 W (typically)
    Environment for indoor use only
    Ambient temperature +10 °C to +30 °C
    Operational capacity guaranteed between +5 °C and +45 °C
    Storage and shipping –10 °C to +60 °C
    Elevation up to 3000 m above sea level
    Relative humidity 15% to 80% for temperatures up to 31 °C; non-condensing, decreasing linearly to 50% relative humidity at 40 °C and 20% at 50 °C
    Safety of electrical equipment in accordance with EN 61010-1/IEC 61010-1 Safety requirements for electrical equipment for mea surement, control, and laboratory use – Part 1: General requirements
    Electromagnetic compatibility in accordance with EN 61326-1/IEC 61326-1 Electrical equipment for measurement, control, and laboratory use – EMC requirements - Part 1: General requirements
    Interference emission Class B (suitable for use in residential areas and areas that are connected to a low voltage network that also supplies residential buildings). The device can therefore be used in both areas.

    Last Updated @ 1/5/2017 6:02:50 PM




    Questions & Answers   Ask Seller

    Recently Viewed Items


    CIMB (MY LABORATORIES SERVICES)

    8003221907

    WITHIN 1 WEEK FOR STOCK, 2-3 MONTHS IF NON-STOCK

    Return policy : subject to review, please check on the spot before accepting

    EQUIPMENT 1 YEARS AGAINST MANUFACTURER DEFECT.

    Questions & AnswersDo you have any questions to ask merchant about this product   Ask Seller

    0.0

    0.0 stars out of 5
    5 star
    0
    4 star
    0
    3 star
    0
    2 star
    0
    1 star
    0
    Share your thoughts with others
    Write a review

    Customers Who Bought This Item Also Bought

    Related Products

    mylaboratories' Best Seller

    Promotion Items

    mylaboratories' Items




    Note : The seller assumes all responsibility for listing this item. Please contact the seller to resolve any questions before or after purchasing the item. Currency is RM (Ringgit Malaysia) unless otherwise noted.
    Back to Top
    lelong class
    Our Affiliates : Lmall.my | Superbuy.my | Pretty.my