Right Power Titan One+ 10KVA (Titan ONE + 10K) UPS
Specifications :
Titan ONE + 10K
|
Capacity (KVA/W):
|
10KVA/10,000W
|
Input
|
|
Input Voltage:
|
208/220/230/240VAC
|
Voltage Range:
|
110~300VAC ± 3 % at 50% load
176~300VAC ± 3 % at 100% load
|
Frequency Range:
|
46~54 Hz or 56~64 Hz
|
Phase:
|
Single Phase In / Single Phase Out
|
Input Power Factor:
|
≥ 0.99 @ 100% load
|
THDI:
|
<4% @ 100% Load, <6% @ 50% Load
|
Output
|
|
Output Voltage:
|
208/220/230/240VAC
|
Output Power Factor:
|
1.0
|
Ac Voltage Regulation (Batt. Mode):
|
± 1%
|
Frequency Range (Synchronized Range):
|
46~54 Hz or 56~64 Hz
|
Current Crest Ratio:
|
3 : 1
|
Total Harmonic Distortion:
|
≦1 % THD (Linear Load), ≦ 4 % THD (Non-linear Load)
|
Waveform:
|
Pure Sinewave
|
Transfer Time (AC Mode To Batt. Mode):
|
Zero
|
Transfer Time (Inverter To Bypass):
|
Zero
|
Overload (Ac Mode):
|
100%~110%: 10min ; 110%~130%: 1min ; >130% : 1sec
|
Overload (Battery Mode):
|
100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec
|
Output Socket:
|
Hard-Wiring (Terminal Block)
|
Efficiency
|
|
AC Mode:
|
94%
|
Battery Mode:
|
91%
|
Battery
|
|
Sealed Lead Acid Maintenance Free Battery - Csb/Yuasa/Panasonic Japan
Battery:
|
12V 9AH x 20pcs
|
Backup Time (Depending On Load):
|
15 - 20 mins
|
Recharge Time:
|
9 Hrs. to 90%
|
Charging Current (Max):
|
1A
|
Status Indication
|
|
LCD Display:
|
UPS Status, Load Level, Battery Level, Input / Output Voltage, Discharge Timer, UPS Fault
|
Audible Alarm:
|
Battery Mode, Low Battery, Overload, Fault
|
Communication
|
|
Interface:
|
RS 232 & USB Port
|
Intelligent Slot:
|
Optional SNMP/AS 400 Relay Card
|
Emergency Power Off:
|
Yes
|
Surge Protection & Filtering
|
|
Spike, Surge & Lightning Protection:
|
Yes
|
Overload, Short Circuit Protection:
|
Yes
|
Physical
|
|
Operating Environment:
|
0-40°C, 20 - 90% Relative Humidity (Non-Condensing)
|
Noise Level:
|
< 58dB @ 1 Meter
|
Dimension (DxWxH)mm:
|
592 x 250 x 576
|
Weight (Kg):
|
83
|
Warranty
|
|
UPS Warranty:
|
3 Years for Electronic Parts and 2 Years for Battery Against Manufacturing Defect
|
*Minimum 32A Rating Input Breaker Needed for 6KVA and 10KVA
*Images shown are for illustration purpose only and product specification may differ from actual product.
**Shipping rate depending on the product dimension, weight and location.
***Kindly PM for stock availability before proceed with payment.
Visit our website:
www.server2u.net (Live chat with our online salesperson Now)
PHONE/SMS CONTACT:
Ms. Soraya: 016-211 4381
Mr. Zeck Khoo: 016-959 8891
Mr. Shafiq: 016-211 4834
Ms. Atikah: 016-961 9881
Mr. Steven: 016-331 9811 (System Consultant)
Office: 03-90811702
OFFICE HOUR:
9 AM to 6 PM (Monday to Friday)
OFFICE LOCATION:
D-55-2, Jalan C180/1,
Dataran C180, Pekan Bt 11,
43200 Batu 9 Cheras, Selangor
Email Address:
Sales and Info: sales@server2u.net
Last Updated @ 6/7/2022 5:23:49 PM
|